Manufacturer of a wide range of products which include ethylene gas detector e2638-c2h4 ethylene detector e2638-c2h4, e2638-voc solvent vapours detector-transmitter, greystone make cmd5b4000 in india, ee800 room transmitter for co2, hydrogen sulfide detector transmitter and series cdt carbon dioxide/temperature transmitter ndir co2 sensor, universal outputs, optional relay.









₹ 35000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Detector Type | Fixed Single Gas |
| Brand | Evikon |
| Model | E2638 |
| Power Source | Supply |
| Measuring Range | Range 0...10 / 0...200 / 0...1500 ppm C2H4 |
| Resolution | 0,1 / 1 / 5 ppm C2H4 |
| Color | Grey |
| Sensor Type | Humidity compensated electrochemical sensor |
| Usage/Application | Industrial |
| Dimensions (L x W x H) | As per datasheet |
Ethylene detector-transmitter E2638-C2H4 is a member of new PluraSens® family of multifunctional measurement instruments.
Applications include chemical and polymer industry, agriculture, fruit storage and ripening and other areas requiring precise measurement of ethylene concentration.
The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime. Due to a special technical solution for humidity compensation (available as an option), the detector may be used even at humidity levels up to 100% RH.
Two relays with closing contact (optional) may be used for remote signalling or concentration control. Two alarm set-points are user settable.
Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.




₹ 17500 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Model Name/Number | E2638-VOC |
| Material | Plastic |
| Brand | Evikon MIC |
| Measurement Range | Up to 0...1000 ppm (toxic range) 0...100% LEL (flammable range) |
| Power Supply | 12...36 VDC (default) 24 VAC or 230 VAC as options |
| Response Time | < 120 s |
Volatile organic compounds detector-transmitter E2638-VOC is a member of new PluraSens® family of multifunctional measurement instruments which is intended for detection of various solvent vapors, e.g. toluene, xylene, ethanol.
Applications include storages, painting chambers and other areas, where toxic or potentially explosive concentration of volatile organic compounds can accumulate.
The instrument utilises a fully calibrated metal-oxide semiconductor gas sensor with excellent repeatability, stability and long lifetime.
According to user's preferences the detector can be ordered for either fire prevention (range 0...100% LEL) or for toxicity prevention (range 0...1000 ppm).
Two relays with closing contact (optional) may be used for remote signalling or concentration control. Two alarm set-points are user settable.
Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.










₹ 18800 / PieceGet Latest Price
| Minimum Order Quantity | 10 Piece |
| Model | CMD5B4110 |
| Brand | Greystone |
| Detector Type | Fixed Single Gas |
| Name of Gases Detected | Carbon monoxide |
| Material | ABS |
| Display Type | Digital |
| Power Source | Power supply |








₹ 19500 / PIECEGet Latest Price
| Brand | E+E |
| Model Name/Number | EE800 |
| Part Number | EE800 |
| Size | Dimensions: EU: W x H x D = 85 x 100 x 26 mm (3.3 x 3.9 x 1") US: W x H x D = 85 x 136 x 26 mm (3.3 |
| Humidity Range | 10 to 90 % RH |
| Gas Type | CO2 |
| Humidity Accuracy | 3% RH |
| Usage/Application | Demand controlled ventilation Heating, ventilation and air conditioning Building automation |
| Output analogue | 0-10 V or 4-20 mA |
| Output digital | Modbus RTU or BACnet MS/TP |



₹ 55000 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Detector Type | Fixed Gas Detector |
| Warranty | 1 year |
| Sensor Life | 5 years |
| Gas detection | Hydrogen Sulphide |
| Colour | Grey |
| Powe Supply | 24V / 230VAC |
| Output | 0-10V / 4-20mA / RS485 |



₹ 9900 / PieceGet Latest Price
| Usage/Application | Demand control ventilation in schools, office buildings, hospitals, and other indoor environments |
| Model Name/Number | CDT-2N40 Carbon Dioxide/Temperature transmitter, wall mount, universal current/voltage output, North |
| Brand | Dwyer Instruments USA |
| Voltage | 16 to 35 VDC or 19 to 28 VAC. |
| Accuracy | CO2: +-40 ppm +-3% of reading; Temperature: +- 1 Degree C @ 25 Degree. |
| Operating Range | CO2: 0 to 2000 or 0 to 5000 ppm (depending on model); Temperature: 32 to 122 DegreeF (0 to 50 DegreeC). |
| Product Weight | 4.4 oz (125 g). |
| Protection Type | Duct mount: NEMA 4X (IP66) for housing only; Wall mount: IP20. |
The Series CDT Carbon Dioxide and Temperature Transmitters accurately monitor the CO2 concentration and temperature in indoor environments to help achieve energy savings. For increased sensor accuracy, a single beam dual wavelength nondispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied* and unoccupied buildings against light source aging effects. The single beam dual wavelength sensor technology provides the highest level of accuracy compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure conditions. In order to achieve a higher level of accuracy, the Series CDT includes digital barometric pressure adjustment and the ability to field-calibrate the sensor. For applications that require visual indication, the wall mount configurations of the Series CDT can be ordered with an integral LCD display. Push buttons are standard on all configurations of the transmitters for access to the menu structure, but wall mount configurations can be ordered without the buttons. To prevent tampering, the action of the buttons can be locked out using an internal dip switch selection.
*For buildings occupied 24 hours per day, it is recommended that calibration be verified every 6 to 12 months depending on application.
Single beam dual-wavelength sensor advantages:
PRODUCT APPLICATIONS





₹ 37100 / PieceGet Latest Price
| Minimum Order Quantity | 1 Piece |
| Detector Type | Fixed Single Gas |
| Name of Gases Detected | Ammonia |
| Brand | Evikon |
| Model | E2608-NH3-E |
| Power Source | Power supply 12...36 VDC (default), 24 VAC or 230 VAC as options |
| Measuring Range | Detection range 0...100 ppm NH3 0...300 ppm NH3 0...1000 ppm NH3 up to 10000 ppm on request |
| Dimensions | H85 x W82 x D55 mm |
| Warranty | 1 Year |
| Material | grey ABS plastic, wall mount, IP65 |
| Alarm Type | 2 x SPST relays (closing contact), 250 VAC / 30 VDC, 5 A max |
E2608-NH3-E
Ammonia Detector
Features
Stable long-life electrochemical sensor
Range 0...100 / 0...300 / 0...1000 ppm NH3
Resolution 1 / 2 / 5 ppm NH3
Two SPST relays
2 × 4-20 mA or 0-10 V, RS485
Description
Ammonia detector-transmitter E2608-NH3-E is a member of new PluraSens® family of multifunctional measurement instruments.
The instrument is intended for leakage control in refrigeration facilities, warehouses etc. It is not recommended to use the device in spaces with constantly high ammonia concentration such as cattle, pig and poultry livestock houses, since it shortens the sensor lifetime.
The instrument utilises a fully calibrated and temperature compensated electrochemical gas sensor with excellent repeatability, stability and long lifetime.
Two relays with closing contact may be used for remote signalling or concentration control. Two alarm set-points are user settable.
Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.


AKHIL Or SACHIN (Sales)
Spectrum Enterprises
Plot No. 91, Flat No. 61, Lucky Apartment, Sector - 15, Kopar Khairne, Navi Mumbai, Thane, Navi Mumbai - 400709, Thane, Maharashtra, India